IM C (current color A3)
IM C2010 / C2510
Smart Operation Panel (SOP) 2.x · GW+ controller · 20 / 25 ppm color
Field notes for this family — not a scanned FSM. Confirm the serial in the book before you order a part.
Covers
- IM C2010
- IM C2510
Field notes
- Smaller IM C. Same SOP/GW+ habits as C4510.
- ADF options differ — confirm the hinge connector before swapping an ADF from a C4510.
- Watch 336/396 after a PCU that was sold as ‘fits all IM C’ — it often does not.
PM interval
PCU ~50–60k, fuser ~100–120k
Key SP numbers
- SP5-810-001SC reset
- SP3-011-001Forced process control
- SP5-990SC history
Unit locations
Fusing unit
Right door
PCUs
Front door
Hot codes on this family
Start here on a call
Enter SP mode
SOP / IM C: Reset → 806182 → hold C. Then 5812# (phone on counter), 5810# (SC reset), 5990# (print SMC).
SC reset (SP5-810)
Clear a latched Level A/B service call after the repair is actually done.
Read SC history
The standing SC is rarely the whole story. History tells you what led up to it.
Forced process control
Run MUSIC / process control after PCU, developer, ITB, or ID sensor work.
Developer initialization
Init TD sensor / developer after a PCU or developer swap. Skipping this is a textbook SC325.