All codes

Service call

SC392

TD sensor initial setting failed

BPCU / developer

Level B — stop, power-cycle may clear

First check

Skipped developer init after a PCU/dev swap is the classic. Run SP3-002.

What it means

TD sensor initial setting failed. Confirm the exact subcode against the FSM for this serial — meaning can shift by generation.

Likely causes

  • Skipped developer init after a PCU/dev swap is the classic. Run SP3-002.

On-site steps

Parts to have on the truck

  • Development unit

SP / reset

SP3-002 then SP3-011 — not SP5-810.

Related codes