All procedures
Parts
PCU replacement
Replace a photoconductor / charge unit and leave process control green.
Applies · IM C, MP C, IM B&W (single PCU)
01Match the part
C2010, C3510, and C4510 PCUs are not a bag of ‘close enough’. Read the part number. Wrong CRUM → 396/397.
02Pull
Front door. Pull the handle straight. Do not stand the drum on the table — light-pipe and park it in the bag the new one came in.
03Contacts
Inspect HV and CRUM contacts in the machine. Toner cakes here cause 302/396 on the new unit.
04Install + init
Seat until the set switch clicks. Install toner if you also changed developer. SP3-002 if required, then SP3-011. Reset PM for that color.
SP numbers
- SP3-002
- SP3-011
- SP7-804